national gypsum1Whether you are at work or play, finding a quiet room is a challenge. Today’s average office worker is allocated 200 square feet per person compared to 500 to 700 square feet in the 1970s. Most new homes have dedicated media rooms with surround sound stereo systems, and even the smallest electronic devices are equipped with speakers and sound effects. Yet research continues to show that children learn better in quiet classrooms and residents tend to sleep better and like their neighbors more if they can’t hear them.

Improving acoustics requires thoughtful planning and using solutions designed to increase Sound Transmission Class (STC) ratings. The higher the STC rating, the less airborne sound is transmitted from one space to another.

Whether designing multi-family housing, health care facilities, schools or corporate offices, begin by identifying the specific acoustical goals. For example, we have a different expectation in a gymnasium than a school library. If possible, architects will try to isolate noisy spaces such as a band practice room. The American Institute of Architects has published STC guidelines for specific adjacencies in healthcare environments.

Higher STC ratings result from reduced airborne sound transmission. There are four things you need to address when trying to stop sound transmission-mass, damping, isolation and limpness. If space were not a constraint, wall mass could be increased, but that is neither practical nor economically feasible.

Architects trying to achieve higher STC ratings have several options, but one of the newer solutions is an acoustically enhanced gypsum board used in place of resilient channel or multiple layers of gypsum board with superior performance. National Gypsum’s solution is Gold Bond brand 5/8-inch SoundBreak XP Gypsum Board. SoundBreak XP is regularly used in commercial and residential developments and is GREENGUARD Children & Schools Indoor Air Quality Certified.

SoundBreak XP used in conjunction with steel studs provides the four properties required to stop sounds transmission-mass, damping, isolation and limpness.

Increasing the mass and limpness of a wall partition increases the amount of sound transmission loss. For that reason metal studs outperform wood studs, and 24 inches on center framing spacing outperforms 16 inches on center framing spacing. The physical properties of steel studs flex rather than transmit vibration, which minimizes sound from vibrating through the wall compared to a wall assembly with wood studs.

national gypsum2A heavier wall has better acoustical performance, and the denser gypsum core adds mass. SoundBreak XP is comprised of a layer of viscoelastic damping polymer sandwiched between two pieces of high-density mold resistant gypsum board, which creates constrained layer damping. The multi-layer panel allows sound to pass through one layer and dissipate into heat energy before passing through the other side. This configuration provides both damping and isolation.

When the depth of the cavity of the partition is filled with acoustical insulation or sound-absorbing material such as fiberglass or mineral fiber insulation, it will increase the amount of sound transmission loss. The sound-absorbing material should completely fill the cavity but not be compacted or compressed in any way.

Sound, like water, will find the path of least resistance and get through any penetration that is not properly sealed. Other areas to address are electrical boxes for outlets, data lines and switch plates. If not properly sealed, sound will leak right through them. Offsetting electrical boxes by one stud space and wrapping the backside of electrical boxes with putty pads after wiring will help reduce noise. Acoustical caulking around the wall perimeter will complete a wall assembly designed for superior acoustical performance.

SoundBreak XP wall assemblies offer a range of STC ratings based on full-scale acoustical tests. Specific assemblies can be found in the Acoustical Selector Guide,(www.nationalgypsum.com/file/SoundBreak%20Tool/SB_selector_5-8.pdf[1]) at www.nationalgypsum.com[2].

 

Mundise Mortimer is the manager, technical marketing of National Gypsum Co., Charlotte, N.C. National Gypsum provides the architectural community with continuing education credits through both online and onsite educational programs related to product application, technical standards and industry trends. Courses teach acoustical terminology, sound reducing solutions, innovative technologies, and design considerations. All programs qualify for AIA/HSW learning units. Visit www.nationalgypsum.com[2] for more information.

Endnotes:
  1. www.nationalgypsum.com/file/SoundBreak%20Tool/SB_selector_5-8.pdf: http://www.nationalgypsum.com/file/SoundBreak%20Tool/SB_selector_5-8.pdf
  2. www.nationalgypsum.com: http://www.nationalgypsum.com

Source URL: https://www.metalarchitecture.com/articles/know-your-products-noise-stopping-solutions/