Night view from Broad Street with illuminated entrance, seal and glass enclosed loggia with “halo” of light at roof.
Energy-efficient dual curtainwall will completely transform federal building
Thanks to the American Recovery and Reinvestment Act of 2009, the Peter W. Rodino Federal Building in Newark, N.J. is about to undergo the transformation of a lifetime. Located in the heart of Newark’s civic center, the 16-story Rodino Building is the largest federal building in the state. Completed in 1968, it has a deteriorated exterior, high fossil fuel usage, and does not meet the current facilities standards of the United States General Services Administration. The ARRA authorized $146 million towards giving the 467,550-square-foot building its first major upgrade in its history.
Façade Options
New York City-based Dattner Architects received the original commission with Richard McElhiney Architects, New York City, from the GSA back in 2005 to perform a modernization and interior renovation of the Rodino building. John Woelfling, architect with Dattner Architects, explains that there were a number of goals for the project, including evaluating the building’s existing precast concrete façade in an effort to create a dignified civic presence for the building and harden it’s shell, making it compliant with the GSA’s current standards for treatment of federal buildings. Additional goals included dealing with the building’s acoustical and energy issues.
Dattner conducted a study of the Rodino building’s existing façade, discovering many cracks and fissures that had occurred over the building’s life, had developed into smalls and were seriously deteriorating the building’s exterior. Woelfling explains that Dattner came up with several different options of how to deal with the façade, such as doing a minor patch and repair job on the cracks and smalls, dealing with the worst and stabilizing the façade. “The problem with that approach is that you’re coming back every five to eight years and re-doing that work for the new cracks that show up,” says Woelfling. “While you’ve solved the problem in the short term, it’s not a real long-term solution.”
The second option was to replace some of the more damaged pre-cast panels and to repair the balance. While this approach had many of the same drawbacks as the first option, it didn’t satisfy some of the project requirements, such as improving the building’s presence, hardening the shell and improving the energy performance.
A third option was to completely tear off all of the precast panels and re-skin the building in a highperformance curtainwall, Woelfling says. While this achieved many of the project goals-improving the civic presence, hardening the building, improving the energy performance-it didn’t make sense in the long run, since this scheme required the building to be vacated and swing space paid for during construction.
“Ultimately we took the best pieces of all the other schemes and combined them into what we ended up with, which was to stabilize the existing panels as best as we could and then wrap the building in a high-performance curtainwall,” explains Woelfling. This solution met all of the programmatic requirements-stabilizing the façade, improving the acoustics, improving the energy performance, hardening the building, keeping it occupied during the renovation-and also had the lowest life cycle costs.
After Dattner completed the study in 2005, the funding for the project wasn’t available, putting the modernization on the shelf for a few years. Flash forward to 2009, and with the help of the ARRA grant, the GSA awarded Dattner a $3.45 million contract to begin the preliminary design work and bridging documents on the project.
A Smart Envelope
The custom curtainwall will be suspended over the building’s existing façade, significantly increasing the building’s energy performance, the comfort of its occupants and the blast resistance of the enclosure, in addition to drastically transforming the building’s identity. The support structure for the curtainwall will be tied directly into the steel frame of the building through W27’s that will transfer to wind load and potential blast load back into the building’s structural slabs.
Additionally, the dual curtainwall is a smart envelope that reacts to environmental conditions. The curtainwall, which is broken into two-story segments that are 26 feet tall, will have a 3-foot interstitial area between the existing façade. Each curtainwall segment consists of operable vents that are glazed, and when the conditions are right, the vents will open up and allow air to come in at the bottom of the cavity, and then exhaust out the top of the cavity, Woelfling explains. In the summer, the vents will be open a large part of the time, and the building will be kept cool through shading and a reduction of solar heat gain. During the winter months, the curtainwall’s vents will remain closed most of the time, allowing the captured solar heat gain to provide a little buffer for the building.
Energy analysis and computational flow studies completed by Dattner show that in the wintertime, the high-efficiency curtainwall will aid in virtually eliminating the heating load for the building. “Through this overclad system, we have significantly changed the energy intensity of this building,” says Woelfling.
Daylighting and glare control are also very important to the curtainwall solution. “We didn’t want to obscure the existing glazing to the extent that we would take away from the amount of daylighting that couldget into the spaces, reducing the amount of electrical load needed for artificial lighting,” Woelfling explains. Sustainable Initiatives
The modernization project has the goal of achieving LEED Silver certification from the United States Green Building Council. In addition to the new energy-efficient dual curtainwall, the project will feature improvements of high-performance lighting, energy-efficient upgrades to the building’s mechanical and plumbing systems, a 60 KW photovoltaic array supported by a steel-structured halo and canopy, and rainwater harvesting. Together, these features are expected to reduce the building’s overall energy use by approximately 32 percent.
Currently there are two large cooling towers and two large chillers in the building’s basement that are going to be replaced with three cooling towers and three chillers-two larger ones and a smaller one of each-that will allow the cooling supply to better match the building’s demand. Additionally, by changing the Delta T on the supply water, condenser water and the chiller water, the building can have smaller pumps with smaller piping, making a more efficient system. On each of the individual floors there will be variable air volume boxes instead of a constant volume system, which will allow for a better controlled space and a better match to the demand of cooling.
With completion anticipated for 2015, the project’s bridging documents are completed and the design-built contract has been awarded to Tocci/Driscoll joint venture, Woburn, Mass. Bovis Lend Lease, Princeton, N.J., is the construction manager, and KlingStubbins, Cambridge, Mass., is the architect of record.
Celebrating the best in federal architecture, the GSA honored the Peter W. Rodino Federal Building modernization project with its On the Boards Engineering Citation at the 2010 Design Awards.